Customization: | Available |
---|---|
After-sales Service: | Free Spare Parts |
Warranty: | One Year, One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Summary
The instrument is designed and made as per T 0625-2011 "Asphalt Brookfield Rotational Viscosity Test (Brookfield Viscometer Methods)" in the Industry standard of People's Republic of China JTG E20-2011Specifications and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering. It is suitable to determine the absolute viscosity of Newtonian liquids and the apparent viscosity of Non-Newtonian liquids. It is widely used for determining viscosities of asphalt, hot melt adhesive, paraffin, high polymer, and other liquids.
I. Main technical features
1. The instrument adopts advanced mechanical design technology and manufacturing process, using micro-computer technology to control speed, collect data and process data. Accurate data acquisition, high sensitivity, reliable test results, easy to use, and good looking.
2. Display selection of white backlight, high brightness LCD display, can directly display the viscosity of the sample, the number of the rotor, speed and other information, data display clear.
3. The test data can show on the screen real time and also output by printer. In addition, the instrument can also connect with PC via RS232 communication port.
4. Choose different models can have different ranges, for measuring different samples.
II. Main technical specifications
1. Measurement range: 100 mPa•s~2×106 mPa•s (If you select the No.30 spindle, the measurement range can be extended to 4×105 mPa•s)
2. Rotor Specifications: No.21, 27, 28 and 29 total 4 pieces of spindles (the No.30 spindle is optional)
3. Rotor speed: (5, 10, 20, 50)r/min
4. Measurement error: ±1% (F•S); (If you select the No.30 spindle, it will be ±3% (F•S)
5. Temperature control range: 45 ºC~200 ºC
6. Temperature control accuracy: ±0.1 ºC
7. Sample cylinder: 20 ml
8. Print output: Needle printer
9. Communication with the PC: RS232 interface
10. Power supply: AC 220V±10%, 50 Hz
11. Ambient temperature: 5 ºC~35 ºC (when the controlling temperature is close to ambient temperature, please run the air conditioner to let the ambient temperature be 5 ºC lower than the controlling temperature)
12. Relative humidity: ≤80%
Other related products: