Customization: | Available |
---|---|
After-sales Service: | Provid |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Automatic Bitumen and Bituminous Mixtures Penetrometer
Summary
1.The instrument is designed and made as per the standards GB/T4509 Standard Test Method for Penetration of Bitumen, T0604 Bitumen Penetration Test in the standard JTJ052-2000 Specifications and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering and ASTM D5.
2.The instrument is suitable to determine the penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation.
3.The penetration of bituminous materials is expressed as the distance that a 100 g±0.05 g standard needle vertically penetrates into the sample without measurable fraction in 5 s at a constant temperature bath of 25±0.1 ºC. It is used for evaluating the consistency of asphalt. The larger the penetration is; the thinner and softer the asphalt is.
4.The instrument can also be used for inspecting industry materials such as solid granule, powder, colloid, as well as food materials such as cream, glycine, etc. It has been widely used in the field of food industry, highway and traffic departments and other departments.
Main technical specifications
1.Measurement range: 0 penetration~600 penetrations;
2.Resolution: 0.1 penetration;
3.Timing range: 0s~60 s, and the error is less than ±0.1 s.
4.Heating power: 200 W;
5.Temperature controlling accuracy: 25±0.1 ºC (Note: the ambient temperature should not be higher than 20 ºC);
6.Data saved: 30 groups;
7.Constant temperature bath: harden glass container;
8.Stirrer: a magnetic stirrer;
9.Standard needle: 2.5±0.05 g and it conforms to the requirements of GB/T4509 and T0604.
10.Shifting holder: It has two ways to adjust the height of standard needle, so it is convenient to let the needle tip just touch the sample surface.
11.Power supply: AC 220 V±10%, 50 Hz.
Standard accessories
No. | Item | Unit | Qty | Remarks | |
1 | Low temperature constant temperature bath | Set | 1 | With 2801F | |
2 | Standard needle(50mm,2.5g±0.05g) | Piece | 3 | ||
3 | Weight (50g) | Piece | 1 | ||
4 | Asphalt sample container | Φ55 × H35 (small sample container) | Piece | 3 | |
Φ70 × H45 (big sample container) | Piece | 3 | Selection of accessories | ||
Φ55 × H70 (special sample container) | Piece | 3 | Selection of accessories | ||
5 | Mercury thermometer (0~50 ºC, scale division is 0.1 ºC) | Piece | 1 | ||
6 | Heat preservation water sink(Heat preservation bath) | Piece | 1 | With 2801F | |
7 | Black rubber hose | Piece | 2 | With 2801F | |
8 | Hose clamp (Ф16 wire hoop) | Piece | 4 | With 2801F | |
9 | Serial port wire | Piece | 1 | ||
10 | Power supply line (250 V 6A) | Piece | 1 | ||
11 | Triangle holder | Piece | 1 | ||
12 | Fuse (2A, Ф5 × 20) | Piece | 3 | Used for penetration Instrument. |
|
13 | Fuse (10A, Ф5 × 20) | Piece | 2 | Used for low temperature water bath. | |
14 | Special displacement test head | Piece | 1 | ||
15 | Stylus printer | Piece | 1 | ||
16 | Regulated power supply (input 220V/50Hz, output 5V/3A) | Piece | 1 | ||
17 | 25-pin data cable | Piece | 1 | ||
18 | Print paper (suitable for the above stylus printer) | Piece | 1 | Except installed in the instrument | |
19 | Temperature setting device | Piece | 1 | ||
20 | Screwdriver (blade width 2.5 mm) | Piece | 1 | For the adjustment of temperature setting device |