• Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500μ m)

Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500μ m)

Type: Static Laser
Sample Feeding: Wet Dispersion, Circulating Sample Feeder & Static
Measuring Range: 0.2 ~ 500μm
Repeatability: <3%
Scan Frequency: 1000times/Second
Pump: 10m, Max Speed: 2800rpm, 10L/Min.
Customization:

Contact Supplier

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PA-POP6LW
Measurement Duration
1-2 Minutes
Model
PA-Pop6lw
Transport Package
Package for Export
Trademark
Xiangyi
Origin
China
HS Code
9027500000
Production Capacity
100 PCS/Month

Product Description

Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m)
PA-POP6LW Semi-auto Wet Dispersion Laser Particle Size Analyzer is basic product, the actual measurement range has reached domestic advanced level, it is a cost effective laser particle size analyzer.


Application
measure the particle distribution of the powder and latex

Principle
Using the phenomenon of light scattering of particle, according to the distribution of scattering light energy, to calculate the size distribution of particles measured. Our instruments own the advantages of wide measurement range, good repeatability, simple operation and etc. through our system integration and optimization for optics, mechanics, electronics and computer.

Report Items
Particle size distribution table, particle size distribution curve, average particle size, median diameter, specific surface area, etc.

Features
  1. Adopt unique scattered light detection around a sphere surface (patent no.:95223756.3), after lens (also known as "reversal" or "converging light") Fourier transform structure, place large angle detectors on proper spherical surface, to realize the accurate focusing of large angle scattered light.
  2. Use integrative laser emitter (patent no.: 00228952.0), effectively reduce the thermal deformation of laser tube, the influence of outside mechanical vibration on the stability of the instrument.
  3. Wet sample feeding system adopts booster pump, top speed can reach 2800 rpm, can effectively realize the circulation of large particles.
  4. Inlet and outlet water solenoid valve adopts Germany Baode imported products, precision control action, durable.
  5. Measurement window material uses high quality optical materials, window components adopt full stainless steel material, wear-resisting, easy to clean, and maintenance is convenient.
  6. Light path system uses fully-enclosed design, preventing dust pollution and outside light pollution.

The Application of Patents and Proprietary Technology
  1. Scattered light detection around a sphere surface (DAS)
    The large angle detectors are placed in a spherical surface to get accurate focusing of large angle scattered light.
  2. Integrated laser emitter
The beam expander and the pinhole filter are integrated in several concentric tubes, and then jointed into one tube with both ends enclosed. It is shock proof, easy to maintain and with stable laser output.
 

Software Function
  • Borland Visual C++ development environment, concise and user friendly operating interface.
  • Easy switch among different types of reports.
  • Auto clear of Electric noise.
  • Sample parameters editing, selecting and saving function.
  • Chinese and English report.
  • Customer size grading function.
  • Multiple ways of selecting "measurement parameters".
  • Multiple document formats.
  • Operating log and measuring log function.
  • Data input function.
  • Statistics of multiple documents.
  • Two distribution models : Rosin-Ramler, multi-wave crest;
  • Two report models: General report, statistics;
  • Two accumulative directions: small to large, large to small;
  • Reports can be exported as Excel format or other text format files;
  • Report items can be set/selected according to customers' requirements.

Specifications
  • Measuring Range: 0.2 ~ 500μm
  • Sample Feeding: wet dispersion, circulating sample feeder & static sample cell
  • Repeatability: <3%
  • Scan frequency: 1000times/second
  • Pump: 10m, max speed: 2800rpm, 10L/min.
  • Measurement Duration: 1-2 minutes
  • Number of Detectors: 43
  • Light Source: He-Ne laser, 2.0 mW, 0.6328 μm
  • Environmental Requirement: Temperature: 5-35°C, Humidity: <85%

Configuration
 
1 Particle Sizer host
2 Sampling system: circulating injection systems and static sample pool
3 Laser particle size analyzer test-specific software
4 Other Accessories

Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m) Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m) Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m) Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m) Semi-Auto Wet Dispersion Laser Particle Size Analyzer (0.2-500&mu; m)

 

Send your message to this supplier

*From:
*To:
avatar Ms. Judy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
36
Year of Establishment
2005-04-06