• -60° C~250° C Industry Hermetic Refrigerating & Heating Circulator
  • -60° C~250° C Industry Hermetic Refrigerating & Heating Circulator

-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator

Type: Water-Cooled
Cooling Method: Water-cooled
Unit Structure: Integral
Selected Voltage: 220V50Hz/380V 50Hz
Compressor Number: 1
Noise Level: Low
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HRHC Series
Application Fields
Chemical
Application Machine
Laser Equipment,Plasma Welding
Certification
RoHS, ISO, CE
Condition
New
Temperature Range
-60°c~250°c
Temp. Accuracy
±1°c
Transport Package
Export Packing
Trademark
Xiangyi
Origin
China
HS Code
8418692090
Production Capacity
100 PCS/Month

Product Description

-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator-60° C~250° C Industry Hermetic Refrigerating & Heating CirculatorApplication:
Reactor Systems Autoclaves, Pilot Systems, Mini Plant Systems, Scale up for Operational Development, Double wall reactors, Advanced-Flow Reactors, Distillation Systems, Material Testing, Combinational Chemistry, Semi conductor Industry, Vacuum Chambers.

Advantages & Functions
  • Hermetic circulation system make sure high accuracy of temperature and extend life time of circulating liquid.
  • Widely working temperatures range from -100°C to +350°Cwithout cooling fluid change
  • Intelligent PID temperature control
  • High stability and reproducibility of process
  • Adopted plate heat exchanger, heating pipeline to improve rate of heating & cooling
  • Widely cooling power range from 0.5 to 500 kW
  • Brilliant 4 inch, 7 inch, 10 inch TFT touch screen with graphic display can be choose.
  • Comprehensive warning and safety functions
  • Rapid cooling down from high temperature (from 300°C).
  • Control software is available which can communication in 200 meter distance. (Optional)
  • Incredibly compact

Structure design
-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator
A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with a expansion of container, expansion of the container and the liquid circulation is adiabatic, it will not in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60°C. The advantages by this design:
  • Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is limited to 60°C), therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced.
  • No volatilization of the heat conducting medium at high temperature.
  • No need to change the heat conducting medium. Continuous control the temperature range to -80°C~190°C, -70°C~220°C, -88°C~170°C, -55°C~250°C, -30°C~300°C without rising the pressure.
Display function
  • All the kind of process control temperatures.
  • Liquid level of the heat conducting medium in the expansion vessel.
  • Indication working status of refrigeration system.
  • Indication working status of heater.
  • Indication working status of circulation pump.
  • Temperature control mode (materials and heat transfer medium).
  • Temperature upper limit and lower limit can be set.
  • Temperature difference between jacket & reactor material can be set.
  • Alarm when liquid is empty.
  • Refrigeration compressor can be set to operate manually or automatically.
  • Clear temperature curve displayed, it can be zoom and exported to computer.
  • Recipe procedure set display
  • Alarm note display
-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator

Principle of process control
Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings. System with feed forward with PV, the master PID loop operation results of the PV output and feed forward signals  as the composite of the settings from the control loop, through such control of the temperature gradient to ensure the accuracy of temperature control system.

High repeatability of results control
 -60° C~250° C Industry Hermetic Refrigerating & Heating Circulator  


Circulation Pump
High temperature resistant low tempera  ture magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.

Electronic expansion valve
Wide temperature range of dynamic temperature control system with electronic expansion valve produced by Emerson company, It can monitor and adjust the number of steps (0~750 Steps / minute) into the motor, precise control the liquid volume from the refrigerant , Improve control accuracy.

Configuration software (Optional)

All dynamic temperature control system HRHC-Series can be connected with the computer.
You can install and record the picture of display on the computer via the configuration software.
  • Communication distance less than 200m.
  • Easily temperature setting
  • Real time control screen
  • Curve Records
  • Program selection
  • Alarm screen recording

Safety protection
Many additional features to ensure the safe operation of the system. For the operation to run not normally appear in the alarm in time and displayed on the touch screen. Phase sequence, leakage protection, refrigeration system high and low voltage protection, overload the pump, compressor overload, high and low level, two independent over-temperature protection, water protection, protection of the circulation line shut.

Connecting Pipe
Items Temp. range Interface port
Fluorine rubber hose -30~200°C Φ12*16  Φ16*22  Φ20* 26
Metal insulation pipe -60~250°C DN15  DN20  DN25  M24*1.5  M30*1.5  M38*1.5


Date interface & software
Standard configuration:
  1. Inputs of PT100 temperature sensor
  2. USB data export interfaces
  3. RS485 interface (MODBUS protocol)
  4. Alarm contact output

Optional:
  1. Inputs of 4 ~ 20mA temperature measurement
  2. Inputs of 4 ~ 20mA temperature setting
  3. Ethernet interface
  4. RS232 interface (MODBUS protocol)
  5. Computer operating software (Must be fitted with Ethernet interface)
  6. External control box with touch screen display

Common Specifications:
  • Control mode: Feed forward PID, PLC control
  • Temperature control: Temperature of material and circulation liquid can be controlled and set
  • Program:20 group programs, 45 segments for each group
  • Protocol: MODBUS RTU / RS 485 Interface
  • Temp. sensor: Circulation medium PT100, raw material PT100 (3 measuring points) 4~20mA (Optional)
  • Control panel: 7 inches color touch screen, temperature curve display & record
  • Safety: With self-diagnosis function; freezer overload protection; high-pressure switch, a variety of security features overload relays, thermal protection devices.
  • Closed loop system: Fully closed system, no oil mist at high temperature, low temperature do not absorb moisture in the air, the system does not increase the pressure because the high temperature, low temperature heat transfer medium in automatic replenishment operation.
-60°C~250°C Industry
Model HRHC-6A25W HRHC-6A38W HRHC-6A60W HRHC-6A95W HRHC-6A130W
Temperature range °C -60°C~250°C
Controller Feed forward PID +Our special dynamic control calculation, PLC controller
Communication MODBUS RTU Protocol, RS 485 Interface
Temp. control Process temperature control mode
Program Editor 20 programs, each program can edit 45 steps.
Temperature feedback Heat-conducting medium feedback PT100, (oil outlet temperature,
oil inlet temperature and heater temperature), Three temperature measuring points.
Process Temperature feedback Raw material process feedback PT100 or 4~20mA input (optional)
Temp. accuracy ±1°C ±1°C ±1°C ±1°C ±1°C
Heating power 25kW 38kW 60kW 95kW 130kW
Cooling capacity
 
250°C 25kW 38kW 60kW 95kW 130kW
100°C 25kW 38kW 60kW 95kW 130kW
20°C 25kW 38kW 60kW 95kW 130kW
0°C 25kW 38kW 60kW 95kW 130kW
-20°C 25kW 38kW 56kW 80kW 90kW
-40°C 18kW 22kW 30kW 45kW 56kW
-55°C 6kW 7.5kW 11kW 15kW 19kW
Circulation pump Max110L/min
2.5BAR
Max150L/min
2.5BAR
Max250L/min
2.5BAR
Max250L/min
2.5BAR
Max250L/min
2.5BAR
Compressor Copeland Copeland Copeland Bock Bock
Evaporator KAORI Plate heat exchanger
Oil separator Emerson
Expansion valve Emerson
Operation panel Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch,
overload relay, thermal protection device, liquid low level protection,
high temperature protection and temperature fault protection.
Closed
circulation system
The whole system is full closed circulation, there is no oil mist at high temperature
and no water vapor at low temperature, pressure do not rise up when system is running.
The system will supplement oil automatically at low temperature.
Refrigerant R-404A R23 mixed Refrigerant
Connection size DN25 PN10 DN32 PN10 DN40 PN10 DN40 PN10 DN40 PN10
Water-cooled type W
(cooling water at 30°C)
8.5m³/h
1.5bar~4bar
14m³/h
1.5bar~4bar
20m³/h
1.5bar~4bar
29m³/h
1.5bar~4bar
38m³/h
1.5bar~4bar
water-cooled condenser Shell and tube exchanger(standard)
Dimension 1500*1000*1750 1800*1200*1750 2050*1450*1750 2300*1450*1750 2750*1600*1850
Weight 980kg 1150kg 1380kg 1750kg 2280kg
Power AC 380V 50HZ
38kW (max)
AC380V 50HZ
58kW (max)
AC 380V 50HZ
85kW (max)
AC 380V 50HZ
30kW (max)
AC 380V 50HZ
180kW (max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS 304
Optional Optional Ethernet interface , configure the computer operating software
Optional Water condenser use plate heat exchanger (request for high quality water)
Optional power 440V~480V 60HZ three-phase
 

-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator


Technological Process 
-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator




Packing
-60° C~250° C Industry Hermetic Refrigerating & Heating Circulator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now