PT-D93-261 Pmcc Pensky-Martens Closed Cup Flash Point Tester

Product Details
Customization: Available
After-sales Service: One Year Free Parts
Warranty: One Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
36
Year of Establishment
2005-04-06
  • PT-D93-261 Pmcc Pensky-Martens Closed Cup Flash Point Tester
Find Similar Products

Basic Info.

Model NO.
PT-D93-261
Power Supply
AC (220±10%)V, 50Hz.
Heating Device
Heating Power: 0 W to 600W, Adjustable
Heating Rate
(1 ~ 12)°c/Min; Controllable and Adjustable.
Stirring Rate
a: (90 ~ 120)Rpm, B: (250±10)Rpm
Maximum Power Consumption
650W
Transport Package
Plywood Packing
Specification
Dimensions (m): 0.42*0.35*0.35
Trademark
Xiangyi
Origin
China
Production Capacity
100 PCS/Month

Product Description


Summary
PT-D93-261 PMCC Pensky-Martens Flash Point Tester is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
 
Main technical features
  1. This instrument is designed as per GB/T261 and ASTM D93.
  2. The heating power is continuously adjustable. The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
  3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
  4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
 
Main technical specifications
1. Power supply: AC (220±10%)V, 50Hz.
2. Heating device:: The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate:: (1 ~ 12)°C/min; Controllable and adjustable.
4. Stirring rate:  Procedure A: (90 ~ 120)RPM, Procedure B: (250±10)RPM
5. Oil cup: (1) Inner diameter: 50.7mm ~ 50.8mm.
                  (2) Depth: 55.7mm ~ 56.0mm 
                  (3) The scribed line depth of capacity of testing oil: 33.9mm ~ 34.3mm.
                  (4) Capacity of testing oil: about 70ml
6. Igniting device: (1) Igniting source: gas (or other civilian fuels, the same below)
                            (2) Electric ignition. Gas flame diameter:3.2mm ~ 4.8mm
7. Thermometers: Mercury-in-glass thermometer. Specifications are as below:
                            (1)Scale -5°C ~ 110°C, division 0.5°C
                            (2)Scale 20°C ~ 150°C, division 1°C
                            (3)Scale 90°C ~ 370°C, division 2°C
8. Ambient temperature: ≤ 35°C
9. Relative humidity: ≤ 85%
10.Maximum power consumption: 650W
11. Dimensions (m): 0.42*0.35*0.35
 Standard accessories
No. Item Unit Qty Remarks
1 Thermometer -5 ~ 110 ºC, each scale division is 0.5 ºC Piece 1 GB / T261-2008
Standard requirement
2 Thermometer 20 ~ 150 ºC, each scale division is 1.0 ºC Piece 1
3 Thermometer 90 ~ 370 ºC, each scale division is 2 ºC Piece 1
4 Driving flexible shaft Piece 1  
5 Latex tube Ф3 250mm Piece 3 One for alternate
6 5A fuse (Ф5 × 20) Piece 2  
7 Thermometer adapter Set 1  
8 Thermometer liner
(Cut suitable length of liner to wrap the lower end of the thermometer, so that the thermometer is just inserted into the thermometer adaptor)
Piece 5  