Low Temperature Water Cooling Circulation Enclosed Chiller Pump

Product Details
Customization: Available
After-sales Service: Free Spare Parts
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
36
Year of Establishment
2005-04-06
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
  • Low Temperature Water Cooling Circulation Enclosed Chiller Pump
Find Similar Products

Basic Info.

Model NO.
LRC Series
Type
Water-Cooled
Cooling Method
Water-cooled
Unit Structure
Integral
Selected Voltage
220V50Hz/380V 50Hz
Compressor Number
1
Noise Level
Low
Application Fields
Electronic
Application Machine
Laser Equipment,Plasma Welding
Certification
RoHS, ISO, CE
Condition
New
Medium Temperature Range
-15°c~30°c / -25°c~30°c
Communication Protocol
Modbus RTU Protocol, RS 485 Interface
Temp. Control
Aset Multifunctional Controller
Temp. Control Optional
Heat-Conducting Medium Outlet Temp. Control
Transport Package
Export Packing
Trademark
Xiangyi
Origin
China
HS Code
8418692090
Production Capacity
100 PCS/Month

Product Description

 Low Temperature Water Cooling Circulation Enclosed Chiller PumpTypical Applications:
 Semiconductor Manufacturing Device Cooling:
Single chip cleaning, printing machine, automatic clamp installation equipment, spraying equipment, ion plating equipment, etching device, single-chip processing device, slicing machine, packaging machine, the temperature of the developer management, exposure device, magnetic part of the heating device, etc.
 Laser Equipment Cooling:
Laser processing, heating part of the welding machine, laser marking device, chemical reaction plant, carbon dioxide laser processing machine, etc.
 Other Industries Cooling:
Plasma welding, automatic packaging machine, mold cooling, washing machine, gold-plated groove, resin molding machine, precision grinding machine, injection molding machine of molding parts, etc.
 Analysis Of Testing Machine Cooling:
Electronic microscope, ICP lighting light source part of the spectrum analysis device, heating part of the spectrophotometer, X-ray analytical device of heat source, automatic pulse heating part of the banner, the light source of atomic absorption spectrophotometer, etc.
CNC machine, machining center cooling of the cooling medium.
Low Temperature Water Cooling Circulation Enclosed Chiller Pump

Features
  • Saving resources; closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.
  • Multi-safety protection, more reliable operation.
  • Brand compressor, cascade refrigeration cooling technologies.
  • Human design, more convenient and flexible.
  • Efficient two-condensate system.
  • Computer-cascade temperature controller, temperature figures display, adjustable unit is 0.1°C, temperature range is -25°C to room temperature,PT100 temperature sensor.
  • Use of cold technology, can guarantee the stability of temperature at low temperature.
  • Can set the temperature difference of compressor on/off.
  • Monitoring the ambient temperature, prevent temperature to be higher in the running system.
  • 10.A variety of fault alarm (over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm).
  • Power on delay protection, three-level cascade system protectors.
  • All parts are safety grounding.
  • Adopt full closed circulation design, no water vapor at low temperature and ensure the purity of cooling medium, in case of ice crystals, provide a long time life of heat transfer liquid.
  • High-performance circulating pump, can guarantee 24 hours continuously running a day.
  • Use plate cool-heat-exchanger, heat transfer efficiency is provided.
Low Temperature Water Cooling Circulation Enclosed Chiller Pump
Low Temperature Water Cooling Circulation Enclosed Chiller Pump

Technical Parameters:
-15°C~30°C / -25°C~30°C
Model LRC-0250N LRC-0400N LRC-0700N LRC-1000N LRC-1450N LRC-2000N LRC-2600N
Medium Temperature Range -15°C~30°C -25°C~30°C -25°C~30°C -25°C~30°C -25°C~30°C -25°C~30°C -25°C~30°C
Temp. control ASET multifunctional controller
Temp. control optional Heat-conducting medium outlet temp. control
communication protocol MODBUS RTU Protocol,  RS 485 Interface
Temp. feedback Heat-conducting medium temperature feedback PT100
Cooling capacity 0°C 1.5kW 2.4kW 4kW 7.5kW 10kW 15.5kW 20kW
-10°C 1kW 1.5kW 2.7kW 6.3kW 8kW 12kW 15.5kW
-20°C 0.55kW 0.8kW 1.5kW 3.5kW 5kW 7.3kW 10kW
Circulation pump Max20L/min
1.5bar
Max20L/min
1.5bar
Max35L/min
1.5bar
Max50L/min
1.5bar
Max75L/min
1.5bar
Max75L/min
1.5bar
Max110L/min
1.5bar
capacity of liquid storage 15L 25L 30L 35L 45L 60L 80L
Compressor Tecumseh Tecumseh Copeland Copeland Copeland Copeland Copeland
Evaporator copper tube
Operating controller 7-inch color touch screen, temperature curve record, excel-format export
Security protection Self-diagnosis function; freezer overload protection; high pressure switch;
overload relay, thermal protection device etc. security protection function.
Refrigerants R-404A
Connection size DN-15 DN20 DN20 DN20 DN20 DN-20 DN32
Product size (air-cooled) 400*600*1050 400*600*1150 500*680*1350 550*680*1450 620*680*1550 750*750*1750 850*850*1850
Weight (air-cooled) 115KG 145kg 180kg 225kg 290kg 340kg 385kg
Power AC220V 50HZ
1.5kW (max)
AC220V 50HZ
2.2kW (max)
AC220V50HZ
3.5kW (max)
AC380V 50HZ
4kW (max)
AC380V 50HZ
5kW (max)
AC380V50HZ
6.5kW (max)
AC380V50HZ
8.5kw(max)
Material Cold rolled steel
Optional Circulation Pump Optional: 35L/min 2.5bar 50L/min 2.5bar 110L/min 2.5bar
Optional SUS304 material
Optional Pressure max. 10 bar circulating pump
Optional Power 220V 60HZ three-phases, 440V~480V 60HZ three-phases
Remark Can make the bigger capacity of water storage as required.


Technological Process 
Low Temperature Water Cooling Circulation Enclosed Chiller Pump
Low Temperature Water Cooling Circulation Enclosed Chiller Pump



Packing
Low Temperature Water Cooling Circulation Enclosed Chiller Pump

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More