Customization: | Available |
---|---|
After-sales Service: | Provid |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Comparison Name | Static volumetric method and BJH analyzer | ||
Product name | SA-2000PS1 type Surface area and pore size analyzer |
SA-2000PS2 type Surface area and pore size analyzer |
SA-2000PS4 type Surface area and pore size analyzer |
Model | SA-2000PS1 | SA-2000PS2 | SA-2000PS4 |
Product Image | H78cm*W50cm*L47cm Weight:32Kg |
H78cm*W50cm*L47cm Weight:36Kg |
H78cm*W72cm*L47cm Weight:46Kg |
Function | Surface area, Microporous, pore size analysis | ||
Testing method | Static volumetric method | ||
analysis station number | 2sample degassing station; 1 P0 test stations; 1sample analysis station; |
2sample degassing station; 1 P0 test stations; 2sample analysis station; |
4sample degassing station; 1 P0 test stations; 4sample analysis station; |
Theory and test report | 1, adsorption and desorption isotherms; 2, BET single point method; 3, BET multi-point method, BET constant C; 4, Langmuir (Langmuir) multi-point method; Langmuir equilibrium constant b; 5, the outer surface area statistical method adsorption layer thickness (STSA) S outside; 6, estimate and report the size and true density; 7, BJH pore volume of pore size distribution; (differential and integral pore volume, pore size, pore size distribution histograms, graphs) 8, MK-plate method (parallel plate model) pore volume, pore size distribution (to complement the BJH method, lamellar structure suitable for materials analysis) 9, t-plot method (Boder) microporous analysis; (V-t diagram, t law pore size distribution) 10, MP method (Brunauer) microporous analysis; (V-t diagram, pore size distribution) (which take into account the different adsorbed material constants different factors than the t-plot method close to the true value) 11, D-R Act (Dubinin- Astakhov) microporous analysis; |
Test Accuracy | Repeatability error is less than ± 1.5% |
Test Range | Specific surface area 0.01m2 / g or more, the microporous 0.35-2nm; mesoporous 2-50 nm; macropores to be 50-500nm; sample types: powders, granules, fibrous sheet material and the like can be loaded into sample tube material |
Advantages and Disadvantages | Surface area and pore size for analysis, especially for the large specific surface area and porosity developed sample resolution, high accuracy, suitable catalysts, molecular sieves and other porous, large surface area of the sample surface area and pore size distribution analysis test. |
Pressure Measurement | Smart investment volume control, the small amount of adsorption sample 2-3min / dividing point, the large amount of adsorption sample 3-5min / dividing point; BET multi-point method 15-30min / set of samples; BET single point method 6-10min / set of samples; Aperture standard test 60-120min / set of samples; Narrow aperture test 120-300min / set of samples; (1, number of samples and the number of stations in each group simultaneously test instrument analysis related; 2, more testing time does not include sample preparation time;) |
Ultimate vacuum | Mechanical pump, 4 × 10 |
Liquid nitrogen Cup | 2L large volume liquid nitrogen Dewar Cup, kept growing up to 100h, 70h continuous testing without adding liquid nitrogen. Another optional 3L micro analysis Dewar Cup, when the insulation is greater than 140h, 90 hours no need adding liquid nitrogen |
Sample pretreatment | Degassing (Normal mode: heating, vacuum; molecular replacement mode: heating, vacuum, nitrogen injection cycle;) |
Pretreatment time | Molecular replacement mode: 60-180min; Normal mode: 120-240min; |
Power supply: | AC 220v ± 10%, the current frequency of 50 Hz, power less than 200 watts |