Hunan, China
Business Type:
Manufacturer/Factory & Trading Company
Main Products:
Number of Employees:
30
Year of Establishment:
2005-04-06
Management System Certification:
ISO 9001, ISO 14001, GMP, ISO 13485
OEM/ODM Availability:
Yes
OEM/ODM Service

Interfacial Tension Meter, Digital Tension Meter, Surface Tensiometer manufacturer / supplier in China, offering High Temperature Spinning Drop Interfacial Digital Tension Meter, Sp-S410 Nir Spectrophotometer, Small Type Vacuum Jacket Glass Reactor -1L 2L 3L 5L Bio Reactor and so on.

Gold Member Since 2017
Audited Supplier
Supplier Homepage Products Interfacial Tension Meter High Temperature Spinning Drop Interfacial Digital Tension Meter

High Temperature Spinning Drop Interfacial Digital Tension Meter

Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 100
Payment Terms: L/C, T/T
Interfacial Tension Measurement Range: 102-10-6mn/M
The Amplification Factor Reading Range: 0-6mm, Accuracy 0.001mm
Microscope Zoom Range: 0.7-4.5X
Transport Package: Plywood Case
Trademark: Xiangyi
Origin: China

You Might Also Like

Loading...

Basic Info

Model NO.
SIT2000H / H2
HS Code
9027809900
Based on SIT2000C type spinning drop interfacial tension instrument, it is developed by the improvement of the classic plug-in injector pipe system, anti-corrosion stainless steel heating system and image acquisition. The main characteristics of this product are high temperature pressure resistance, and acid and alkali resistance, H2-type is mud acid resistance. The operation is easier and more stable. The main application areas are: oil EOR (chemical flooding) indoor study and site monitoring; study of surfactants, detergents, emulsions and foams; research fuel oil, lubricants, paints, inks and coatings; pharmaceutical, paper research products, photographic materials, pesticides and so on.
 
 Feature
1, The instrument improves the quartz glass tube pluggable manner, spring thimble against the sample tube, automatically pop up when removing the sample tube easily broken. When injecting the sample into the test again, easier to clean, more convenient operation. Acid and alkali, especially for mud acid and other substances in the oil sector. When injecting the sample into the test again, easier to clean, more convenient operation. Since the inner sleeve made of stainless steel and stainless steel rotor, expansion coefficient of convergence is conducive to temperature conductivity, the material is not susceptible to corrosion and rust, high concentricity, easier to maintain sample tubes horizontally stable, easy to shake.
2, With electric heating temperature control system, capable of constant temperature experiments. The instrument uses a precise PID temperature control technology, heating assembly with a new corrosion resistant stainless steel design, fast heat conduction and easier to uniformly heat the sample tube not need to meet other temperature control devices.
3, Servo motor control system upgrade, motor control and stability;
Of the German imports of US imports of high-speed motor and encoder control technology, servo control system has a complete motor control system upgrades and better compatibility, speed control up to 14,000 rpm / min, speed control accuracy is ± 5 rev / points, the control points up to 500 points, more accurate, more convenient manipulation.
4, Using the latest precision LED control technology while updating the high-speed acquisition and trigger mode CCD image acquisition under low-speed and high-speed rotation conditions are not flashing screen, the image is sharper edge interface, useful for analyzing oil samples turbid fine features.
5, The master program is Windows interface, easy operation, the image as a standard BMP file that can be stored in print. The program uses the world's leading computing technology interfacial tension measured value, simply press the "test", our software automatically controls the speed camera, save the images to calculate interfacial tension value, showing the measured values, the process without human intervention, so as to effectively avoid the human factors on the measured value. You can record the value of interfacial tension with time, speed, temperature changes and all measured values are stored in the database, and export directly to EXCEL documents to be displayed in real-time graph of the measured values. User-friendly software design, powerful database management manages all test data.
6, Low-noise electric viewfinder mechanism interface button operation, simple and convenient. Three leveling design makes it easy to control droplets in the range of available window.
 
Configuration list
1High temperature pressure chamber 1pcs
2Imports of high-speed motor (14000rad / min) 1pcs
3Pressure system (2Mpa) 1set
4Precision electric temperature control system 1set
5Homing drip system 1set
660 Acquisition System 1set
7Needle sets 2pcs
8Long and short needle 4pcs
9Quartz tube 8pcs
10Plug 4pcs
11Application softwaresoftware1set
12Instructions 1pcs
13Operating Manual Electronic Edition 1pcs
 
 
Technical indicators
Measurement mode: capture spinning drop image, the recording centrifuge tube speed, measuring the image geometry, calculated interfacial tension by the formula
modelSIT2000HSIT2000H2
 
Interfacial tension measurement range102-10-6mN/m102-10-6mN/m
The amplification factor of reading range0-6mm       accuracy0.001mm0-6mm      accuracy 0.001mm
Microscope zoom range0.7-4.5X0.7-4.5X
CCD camera resolutionDigital: 752 * 480 (360 000 pixels)Digital: 752 * 480 (360 000 pixels)
Video capture system60 frames / second high-speed acquisition60 frames / second high-speed acquisition
Lens ControlX-axis manual control viewfinder fine tuning 0.01mm
Y axis adjustment microscope focal length 0.01mm
Z-axis adjustment of the position of the imaging lens 0.01mm
Manual tracking droplets
X-axis motor control viewfinder fine tuning 0.01mm
Y axis adjustment microscope focal length 0.01mm
Z-axis adjustment of the position of the imaging lens 0.01mm
360 electric turret control
Automatic tracking droplets
Motor control range1000-14000rev/min1000-14000rev/min
Motor control accuracy± 5 rev / min (RPM)± 5 rev / min (RPM)
Motor speed controlPID single point of control rasterPID single point of control raster
Heating system temperature rangeroom temperature -150 degrees Celsius
pressure systems20atm
Temperature resolution±0.01ºC ±0.01ºC 
heating methodUS Pt thermal resistance heatingUS Pt thermal resistance heating
Temperature display deviceThermocouple program PID control accuracy of 0.01 Thermocouple program PID control accuracy of 0.01 
The external interface of the constant temperature water bathoptional 
Sample tube for measuringInner diameter φ4mm,φ2mm ( no mud acid resistance ,but corrosion resistance)Inner diameter φ4mm,φ2mm ( mud acid and corrosion resistance)
Sample tube fastening method The outer wall of the plug is matched with the inner wall of the rotating shaftThe outer wall of the plug is matched with the inner wall of the rotating shaft
Communication interfaceRS232serie port
Or USB2.0 universal inter face;
Software System Index
Calculated based on the interfacial tension1, the automatic up and down Richard boundary line, on both sides of the boundary between the calculated distance and automatically calculate the interfacial tension
2, you can manually adjust the measured value of secondary results and save operation marks
3, database data management
Calculation modeAutomatic, manual adjustments may be second adjustment  and marks recorded
Magnification calibration functionVertical horizontal magnification calibration (correction factor for a variety of sizes)
Database ManagementHistorical data are saved and the law with database management, historical data can be found, the second adjustment marks and the recording operation can be exported to EXCEL documents and BMP image
Software control functionTemperature, motorTemperature, motor, viewfinder X-axis motor
Camera modeSingle shooting or interval shooting (for example, every 5 minutes interval timer shooting can be a long record)