Handheld Octane Cetane Analyzer, ASTM D 2699

Product Details
Customization: Available
After-sales Service: One Year Free Parts
Warranty: One Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
36
Year of Establishment
2005-04-06
  • Handheld Octane Cetane Analyzer, ASTM D 2699
  • Handheld Octane Cetane Analyzer, ASTM D 2699
  • Handheld Octane Cetane Analyzer, ASTM D 2699
  • Handheld Octane Cetane Analyzer, ASTM D 2699
  • Handheld Octane Cetane Analyzer, ASTM D 2699
  • Handheld Octane Cetane Analyzer, ASTM D 2699
Find Similar Products

Basic Info.

Model NO.
PT-OCA-101
Model
PT-Oca-101
Measurement Item
All Kinds of Gasoline
Octane Measurement Range
40-120 (Accuracy 0.5)
Cetane Number Measuring Range
20-100 (Accuracy 1)
Data Display
Digital Display
Transport Package
Plywood Packing
Specification
Host: 100mm × 200mm × 40mm
Trademark
labgeni
Origin
China
Production Capacity
100 PCS/Month

Product Description

Handheld Octane Cetane Analyzer, ASTM D 2699Handheld Octane Cetane Analyzer, ASTM D 2699Handheld Octane Cetane Analyzer, ASTM D 2699Handheld Octane Cetane Analyzer, ASTM D 2699Handheld Octane Cetane Analyzer, ASTM D 2699Handheld Octane Cetane Analyzer, ASTM D 2699

Test Standard: ASTM D 2699-86, ASTM D 2700-86 , ASTM D 4737-03, ASTM D613, EN ISO 5165

    
Whether in the field or in the laboratory, the PT-OCA-101 analyzer is the leader in portable rapid analysis instruments . The PT-OCA-101 is designed to produce analytical instruments for gasoline, diesel, motor oil and transformer oil .

The rapid measurement method of petroleum product parameters is more efficient than the traditional method, so it has become a trend for this instrument to penetrate into the petroleum product quality measurement instrument market.

PT-OCA series analyzers---octane number analyzer, and petroleum product low temperature parameter analyzer, are used to detect the parameters of diesel oil , engine oil and aviation kerosene. These instruments are widely used in the quality inspection of petroleum products. Portable octane number analyzer is often used for on-site analysis of octane number of motor gasoline, corresponding to motor method and research method ( RON and MON ), and can also be applied to cetane number analysis of diesel . In addition , the temperature of the analyzed liquid and the freezing point of diesel oil can also be measured , and the measurement results are displayed on the LCD liquid crystal display.

PT-OCA-101 octane number analyzer is widely used all over the world. Its measurement method conforms to international standards: octane number measurement conforms to : ASTM D 2699-86, ASTM D 2700-86. Diesel cetane number measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.

Measurement principle
The principle of the octane number analyzer is to measure the insulation permeability of gasoline octane number and cetane number of diesel oil and the electric charge characteristic of electromagnetic induction . The result is determined by measuring the dielectric properties of the sample and comparing it with known parameters stored in memory . The instrument is very sensitive and can measure small changes in dielectric parameters. It can detect petroleum product parameters such as octane number and cetane number.

Main functions and features
  • Measuring gasoline octane number, diesel cetane number
  1. Measure the condensation point of diesel oil, measure the purity of oil
  2. Multi-oil measurement mode can be set, methanol gasoline, ethanol gasoline, blended gasoline, etc. can be detected
  3. Transformer Oil Split Voltage Measurement , Transformer Oil Dielectric Dissipation Measurement
  4. Conductivity measurement of fuel oil More comprehensive and accurate measurement of various data of petroleum products
  5. Repeatable margin of error is 0.5 octane units
  6. Absolute errors are close to static measurements, less than 0.5 octane units.
  7. Can measure various gasolines with additives
  8. Simultaneously display RON, MON and anti-knock index (AKI).AKI=(RON+MON)/2.
  9. Measure diesel cetane number, diesel type and condensation temperature
  10. Powerful processing chip can process data quickly and accurately, compatible with WINDOW system
  11. With temperature correction, low cost of use
  12. With printing function
  13. Simple and easy to operate, small in size, easy to carry, anti-vibration, anti-solvent, and sealed.
  14. 240*80, advanced OLED colorful 2.8-inch large screen , Chinese and English display , suitable for low temperature environment , power indicator , external low-voltage power supply.

Specifications
 
MODEL PT-OCA-101
Measurement item All kinds of gasoline
Octane measurement range 40-120 (accuracy 0.5)
Cetane number measuring range 20-100 (Accuracy 1)
Data Display Digital Display
Measurement time per sample <10sec
Instrument current consumption 30mA
battery life l000hours
Operating temperature range -10ºC ~ +40ºC
Operating relative humidity 30% ~ 80%RH
Operating atmospheric pressure 64~106kPa
size Sensor 60*100mm
Host 100*200*41mm

 


 