• Bubble Method for Pore Size Distribution Calculation Analyzer
  • Bubble Method for Pore Size Distribution Calculation Analyzer
  • Bubble Method for Pore Size Distribution Calculation Analyzer
  • Bubble Method for Pore Size Distribution Calculation Analyzer
  • Bubble Method for Pore Size Distribution Calculation Analyzer

Bubble Method for Pore Size Distribution Calculation Analyzer

After-sales Service: Provid
Warranty: 1 Year
Customized: Non-Customized
Structure: Desktop
Certification: CE
Application: Lab
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SA-2000 PB
Type
Measurement Type
Aperture Test Range
0.02-500um;
Pressure Sensitivity
± 0.05 Mbar;
Flow Sensitivity
± 0.5ml / Min
Model
SA-2000 Pb
Size
Length 72cm Wide and 55cm High 48cm
Nw
35kg
Transport Package
Plywood Case
Specification
Size: Length 72cm wide and 55cm high 48cm NW: 35Kg
Trademark
Xiangyi
Origin
China
HS Code
9027809900
Production Capacity
100

Product Description

Description:
SA-2000PB Bubble Method for Pore Size Analyzer can accurately test maximum aperture diaphragm ,the smallest aperture, average pore size, pore size distribution and infiltration rate of the filter, fabrics, fibers, ceramics, sintered metal and other materials, applicable to the development, production filtration materials and related research institutes and business users.
 
Applications:
Membrane, fabric, fiber, paper, ceramics, sintered metal, rock, concrete and other materials through hole testing the pore size and permeability.
 
Product Features:
  • Aperture test range: 0.02-500um;
  • Multi-sample cell design for different size samples, special samples can be individually designed;
(Patent Title: having to adapt to a variety of sample sizes Bubble Method for Pore Size Analyzer   patent pending number: 201420148785.2)
  • Effect: 1, can be adapted to a variety of sizes and types of sample cells to test films of different diameters, no need for multiple sample cell; 2, test the hollow fiber membrane; 3, no need for the sample cell at the top of the intake pipe structure, easy installation and removal ;
  • Run with automatic vacuum wet assisted device can greatly accelerate the infiltration time and improve test efficiency over 50%;
(Patent name: a bubble pressure method to help run the vacuum apparatus Pore Size Analyzer   patent pending number: 201420148359.9)
  • Function: 1. Run the vacuum assist device to increase the infiltration efficiency; 2, host integration, easy to operate; 3, rapid opening and closing structure;
  • According to the sample ,different kinds of liquid infiltration optional;
  • Double precision flow sensors, flow segment measurement, complementary range, automatic switching;
  • Double-precision pressure sensor, a stress test segment, the program automatically determine, automatic switching;
  • All stainless steel pipes, metal seal, good sealing, high pressure resistance, corrosion-resistant;
  • Full automatic intelligent operation, without human on duty, pro-operating real voice prompts;
  • Detailed running log of instrument display and recording, can be accurate to the second, the whole experimental records can be traced back;
  • Number of patented technologies guarantee the stability and accuracy of the instrument;
 
Performance Parameters
Analysis function Bubble point diameter (maximum pore diameter); mean flow pore diameter (average pore diameter); the smallest aperture; Pore size distribution, the cumulative / differential flow distribution; gas permeability; dry and wet gas flow rate;
 
Testing process Automatic;
 
Run the vacuum assist device The instrument has automatic vacuum to help embellish device, you can customize the number of automatic vacuum-wetting and duration;
 
Aperture test range 0.02-500um;
Pressure test range 0-1bar, 0-40bar; imported high-precision dual-pressure sensors, pressure range segment, complementary range, automatic switching;
 
Flow test range 0-1L / min, 0-100L / min; imported high-precision dual-flow sensor, flow range segment, complementary range, automatic switching;
 
Dedicated sample cell Standard: Round;
Diameter 13mm (accommodate sample thickness 0-6mm);
Diameter 25mm (accommodate sample thickness 0-7mm);
Diameter 47mm (accommodate sample thickness 0-9mm);
Other shapes and sizes can be customized;
 
Test Accuracy Pressure sensitivity: ± 0.05 mbar;
Flow Sensitivity: ± 0.5ml / min;
 
Gas lines All stainless steel pipes, metal seal, sealing, high pressure, corrosion resistance, high durability;
 
Instrument Accessories Key components of pressure sensors, flow sensors, valves, piping, fittings, and all imports;
 
Instrument Specifications Size: Length 72cm wide and 55cm high 48cm, NW: 35Kg, voltage: AC220v ± 5%, less than 1000 watts of power.
 
 

Bubble Method for Pore Size Distribution Calculation Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now