• 6 Channel Rapid Auto Solvent Extractor, Ase
  • 6 Channel Rapid Auto Solvent Extractor, Ase
  • 6 Channel Rapid Auto Solvent Extractor, Ase
  • 6 Channel Rapid Auto Solvent Extractor, Ase

6 Channel Rapid Auto Solvent Extractor, Ase

After-sales Service: Free Spare Parts
Warranty: One Year
Model: Pre-Ase600
Working Channel: 6 Channels
Transport Package: Wooden
Specification: 870*630*815 (mm)
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PRE-ASE600
Trademark
Labxyi
Origin
China
Production Capacity
100 PCS/Month

Product Description

6 Channel Rapid Auto Solvent Extractor, Ase6 Channel Rapid Auto Solvent Extractor, Ase6 Channel Rapid Auto Solvent Extractor, Ase6 Channel Rapid Auto Solvent Extractor, Ase

Introduction to the
 
instrument

PRE-ASE600 is an automatic device for extracting organic components from a variety of solid or semi-solid samples. Fast solvent extractant is a widely used technology in the market because of its extraction efficiency and sample flux are far better than other traditional extraction methods.

Application area
  1. Environment: soil / solid waste kind of hazardous substance residues, pesticides / herbicides, etc.;
  2. Food: food pesticide residues, food additives, etc.;
  3. Agriculture: pesticide residues in crops, oil in extracted seeds, etc.;
  4. Medicine: extraction of active ingredients, natural products, pesticide residues detection;
  5. Others: polymer industry, criminal investigation, petrochemical industry, etc.;

Functional configuration
  1. 6 channels can be handled at the same time (also set to work only 2 and 4 channels according to the method);
  2. Quick boot without waiting, 10-inch touch screen, full Chinese interactive interface, easy to understand, easy to operate;
  3. Can be input and edited by a variety of different application methods for storage;
  4. Drawer-type high-power heating module, extraction pool loading and unloading is convenient and rapid heating;
  5. Large-flux high-pressure infusion pump, rapid fluid addition and pressure;
  6. With the external gas source pressure detection system, will automatically prompt when the pressure is insufficient;
  7. Safety and environmental protection: adopt closed treatment to reduce the volatilization of organic solvents;
  8. Many extraction pool sizes and meet the requirements of different sample processing capacity; (can be customized according to customer requirements)
  9. The infusion pump can automatically adjust the pump speed according to the difference of the channels in the sample extraction pool;
  10. High degree of automation, reduces user operation and improves security;
  11. Each channel has a separate inlet valve and outlet valve and pressure sensor to prevent cross-contamination;
  12. Have leakage alarm function during the boost process; actively stop operation during solvent leakage;
  13. With mechanical overpressure protection function, program overpressure monitoring and automatic pressure relief electronic overtemperature protection function;
  14. Speed: 6 samples can be processed within 20 minutes, and 96 samples can be processed in a working day;


Main technical parameters
MODEL PRE-ASE600
Working channel  6 channels
Add fluid flow rate  100 ml/min
Flow accuracy  Si 1%
Upper working pressure limit  20MPa
Pressure range  0.3-20 Mpa
independent pressure measurement of each channel
Pressure accuracy  ± 1% of fuu scale
Extraction time  20min
Extraction pool specification  34ml
optional 11ml, 22ml, etc
Sample treatment size  10-30g
Solvent consumption  30-150 ml/g
Collection bottle specifications  200ml
optional 60ml, 120ml, and other different specifications of collection bottles
Heating temperature  150ºC
Temperature control accuracy  ± 1ºC
Temperature control gradient  0.1ºC
Proportional valve channel  4 channels
(four solvents can be used at the same time)
Nitrogen inlet pressure  0.5-0.8Mpa
Hybrid accuracy of proportional valve  ± 2%
Operating voltage  AC200~240V
Voltage frequency  50-60 Hz
Peak power  about 1.5KW
Environmental conditions  indoor use
Effective instrument size (L*W*H)  870*630*815 (mm)
Instrument weight  about 120kg

Applied range
It is mainly used to extract organic components in various solid or semi-solid samples, and the instrument meets the following standards:
  1. Measurement method of 405 pesticide residues in Gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry
  2. Determination of 475 pesticides and related chemicals in Gas chromatography-mass spectrometry
  3. Measurement of various ginsenosides in ginseng by liquid chromatography-UV detection method
  4. Pesticide residues in tea by gas chromatography / mass spectrometry method
  5. Organic analysis sample pretreatment method
  6. Extraction and pressurized fluid extraction method of organic matter from solid waste
  7. Soil and sediment, organic matter extraction and pressurized fluid extraction method
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now