• -25° C~200° C Refrigeration Heating Temperature Control System
  • -25° C~200° C Refrigeration Heating Temperature Control System

-25° C~200° C Refrigeration Heating Temperature Control System

Type: Water-Cooled/Air-Cooled
Cooling Method: Water-Cooled/Air-Cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 1
Noise Level: Low
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HRHC-AH Series
Application Fields
Chemical
Application Machine
SUS Reactor, Temperature Difference >150°c
Certification
RoHS, ISO, CE
Condition
New
Temperature Range
-25°c~200°c
Temp. Control
Material Process Control
Transport Package
Export Packing
Trademark
Xiangyi
Origin
China
HS Code
8418692090
Production Capacity
100 PCS/Month

Product Description

-25° C~200° C Refrigeration Heating Temperature Control System-25° C~200° C Refrigeration Heating Temperature Control System

Is applied to SUS Reactor, temperature difference >150
°C
Rapid cooling at high temperature reaction
Polymerization reaction
Rapid heat-up and cool-down temperature

 Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

 Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.

-25° C~200° C Refrigeration Heating Temperature Control System

Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reduce the demand of heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorb the moisture and volatile.


Advantage:
  • Wide working temperatures
  • Previously unachievable performance
  • Intelligent temperature control
  • Maximum process stability and reproducibility
  • Adop plate heat exchager,Pipeline heating,the fastest heating and cooling rates.
  • High cooling power
  • Large temperature range without fluid change
  • Closed system,extend thermal fluid lifetime
  • Incredibly compact
  • 7-inch,10-inch color TFT touch screen display
  • Comprehensive warning and safety functions
  • Rapid cooling down from high temperature
  • Use magnetic drive pump,solve the circulation pump leakage

Application:
  • Reactor Systems Autoclaves
  • Pilot Systems
  • Mini Plant Systems
  • Scale up for Operational Development
  • Double wall reactors
  • Advanced-Flow Reactors
  • Distillation Systems
  • Material Testing
  • Combinational Chemistry
  • Semiconductor Industry
  • Vacuum Chambers

Specifications:
Model HRHC-AH235W
HRHC-AH235
HRHC-AH255W
HRHC-AH255
HRHC-AH270W
HRHC-AH270W
HRHC-AH2A0W
HRHC-AH235
Temperature range °C -25°C~200°C
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Material process control
Program Editor 20 programs, each program can edit 45 steps
Communication protocol   MODBUS RTU Protocol,RS485 interface
Temperature feedback The temperature of four points: the inlet and outlet of heat-conducting medium, heater and material in reactor(External temperature sensor)
Refrigeration host Can set refrigeration host temperature independently
Temp. accuracy ±1°C ±1°C ±1°C ±1°C
Heating power 3.5kw 5.5kw 7kw 10kw
Cooling capacity 200°C 3.5kw 5.5kw 7kw 10kw
100°C 3.5kw 5.5kw 7kw 10kw
20°C 3.5kw 5.5kw 7kw 10kw
-5°C 3kw 4.5kw 6.6kw 8kw
-20°C 1.8kw 2.8kw 3.8kw 4.6kw
Circulation pump Max 35L/min 2bar Max 50L/min 2bar Max 75L/min 2bar Max 110L/min 2bar
Compressor Copeland Copeland Copeland Copeland
Expansion valve Danfoss Danfoss Danfoss Danfoss
Evaporator KAORI Plate heat exchanger
Operation Panel  7-inch color touch screen controller, temperature curve record, data export to Excel format
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigarant R-404A
Connection size DN20 DN20 DN25 DN32
Water-cooled type W(cooling water at 20°C) 800L/H  1.5bar~4bar 1200L/H 1.5bar~4bar 2000L/H 1.5bar~4bar 2900L/H 1.5bar~4bar
Dimension(mm) water-cooled 500*680*1250 500*680*1250 500*680*1250 500*680*1250
air-cooled 500*680*1450 500*680*1450 500*680*1450 650*700*1650
Weight water-cooled 160kg 235kg 315kg 390kg
air-cooled 195kg 265kg 355kg 425kg
Power AC380V 50HZ 6KW(max) AC380V 50HZ 8KW(max) AC380V 50HZ 11KW(max) AC380V 50HZ 14KW(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304
 

Technological Process:
-25° C~200° C Refrigeration Heating Temperature Control System
-25° C~200° C Refrigeration Heating Temperature Control System



Packing
-25° C~200° C Refrigeration Heating Temperature Control System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now