Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985

Product Details
Customization: Available
After-sales Service: Free Spare Parts
Warranty: One Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
36
Year of Establishment
2005-04-06
  • Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985
  • Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985
  • Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985
Find Similar Products

Basic Info.

Model NO.
PKT-OP110
Brand
Labxyi
Customized
Customized
Portable
Portable
Certification
CE
Gas
O2
Type
Coulometric Sensor Method
Model
Pkt-Op110
Repeatability
0.01 or 2%, Whichever Is Larger
Resolution
0.0001 Cm3/(M2 ·24h ·0. 1MPa)
Temperature Control Range
15~450ºC
Temperature Control Accuracy
+0.1°c
Humidity Range
0%Rh 5-90%Rh.100%Rh
Transport Package
Carton
Specification
380 × 625× 386 mm
Trademark
labxyi
Origin
Hunan
Production Capacity
100 PCS/Month

Product Description

Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985

Introduction

This product is based on the test principle of coulometric oxygen sensor, and is designed and manufactured with reference to ASTM D3985 and other standards. Adopting high-precision imported oxygen sensor, this tester has high test accuracy. It is suitable for the oxygen permeability test of films, sheets, papers, packages and related materials in the fields of food, medicine, medical devices, daily chemicals, photovoltaic electronics, etc. It provides high-efficiency oxygen transmission rate detection for a wide range of high, medium and low oxygen barrier materials.

Test Principle
PKT-OP1100 2.0 Oxygen Transmission Rate Tester adopts the principle of coulometric sensor method. The pre-treated sample is fixed in the middle of the test chamber, high-purity oxygen
flows in the upper chamber of the film, high-purity nitrogen (carrier gas) flows in the lower chamber, oxygen molecules diffuse through the film into nitrogen on the other side, and carried to the sensor by the flowing nitrogen. And the oxygen transmission rate is calculated
by analyzing the oxygen concentration measured by the sensor.
Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985


Standard
ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1037, ISO 15105-2, JIS K-7126-B, DIN 53380-3, YBB 00082003

Technical Specifications
Item Technical Parameters

Test range
0.01~1000 cm3/(m2·24h·0.1MPa)
up to 260000 cm³/(m2·24h·0.1MPa)
can be measured through the mask)
Repeatability 0.01 or 2%, whichever is larger
Resolution 0.0001 cm3/(m2 ·24h ·0. 1MPa)
Temperature control range 15~45ºC
Temperature control accuracy ±0. 1ºC
Humidity range 0%RH ,5~90%RH, 100%RH
Humidity Control Accuracy ±2%RH
Permeable area 50.24 cm2
 (custom fittings, down to 0.785 cm2)
Sample size Φ100 mm
Sample thickness ≤3 mm
Sample quantity 1piece
Item Technical Parameters
Carrier gas flow 5~ 100 mL/min
Carrier gas pressure ≥0. 1 MPa
Pneumatic pressure ≥0.3 MPa
Dimensions 380 ×625×386 mm
Power 450 W
Power supply AC 220 V ,50 Hz
 
Application
Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985

Factory configuration

Standard
configuration
Power line, communication line, sample cutter, sealing grease, metal air tube,
terminal ferrule joint, terminal ferrule joint, reference material, special
wrench, syringe, sealing ring, fork wrench, Phillips screwdriver, mouse
Optional Computer, measurement certificate









User provide
1. Standard laboratory environment;
2. Power requirements: 220V regulated power supply with three holes and
three positions with a switch socket;
3. Computer requirements: standard configuration (Windows10, with a
nine-pin serial port);
4. One bottle of oxygen, the purity must be above 99.999%, with a pressure
reducing valve, and the output range is 0-0.4 Mpa;
5. One bottle of nitrogen, the purity must be above 99.999%, with a pressure
reducing valve, the output range is 0-0.4 Mpa.
Note: Xiangyi Instrument(Xiangtan) Limited has always been committed to the innovation and improvement of product performance and function. For this reason, product technical specifications and appearance will be changed accordingly. The above situation will not be notified. The company reserves the right of modification and final interpretation.
Pkt-Op110 Coulometric Sensor Method Oxygen Permeability Analyzer, ASTM D3985
Service Commitment
Free packaging inspection technical support.
- One-year warranty for instrument, free software upgrade service, and lifetime free technical support.
- Free to the factory to train the operation of the instrument, qualified people issued graduation certificates, free accommodation and food.
- Instrument "trade-in" policy and provision of backup instruments in case of failure.
- There is a testing center (CNAS L8185) to provide incoming sample testing and sample data comparison services.
- Set up a Reference Standards Development Center to provide calibration services.
                     

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More