• Woa-900 Infrared Spectroscopy Petroleum Analyzer
  • Woa-900 Infrared Spectroscopy Petroleum Analyzer
  • Woa-900 Infrared Spectroscopy Petroleum Analyzer
  • Woa-900 Infrared Spectroscopy Petroleum Analyzer

Woa-900 Infrared Spectroscopy Petroleum Analyzer

Appliance: Food Analysis, Medical Research, Biochemistry
Portable: Non Portable
Certification: RoHS, CE, ISO9001
Type: Infrared Spectroscopy Oil Analyzer
Detection Limit: 0.02mg/L
Wave-Number Range: 3400cm-1~2400cm-1(2941nm~4167nm)
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
WOA-900
Absorbency Range
0.0000~2.0000au (Transmittance 100~1%T)
Minimum Detectable Concentration
0.001mg/L (Enrichment Extraction Method)
Maximum Measured Concentration
10000mg/L (Dilution Gaging)
Transport Package
Carton/Plywood
Trademark
Xiangyi
Origin
China
HS Code
9027100090
Production Capacity
100 PCS/Month

Product Description

Meeting the standard: Conform to national standard"HJ637-2012 water quality the determination of petroleum and animal and plant oil Infrared photometric method"

Technical principle: According to HJ637-2012 standard, extract the oil material in the water using tetrachloromethane, measure the total extracts, extract liquor adsorb via adsorb magnesium silicate, after removing polar material such as the animal and plant oil, determine oil type. The total extracts and the content of petroleum are calculated by absorbance A2930,A2960 and A3030 in the spectrum band ,wave number 2930cm-1(stretching vibration of C-H key in CH2 group ), 2960cm-1(stretching vibration of C-H key in CH3group), 3030cm-1(stretching vibration of C-H key in aromatic nucleus ).The content of animal and plant oil are calculated by the difference of total extractor and oil content.

Using department of instrument:
Environment monitor system, petrochemical, hydrology and water conservancy, water supply company, sewage treatment works, thermal power plant, iron and steel enterprise, teaching and research work in university, agricultural environmental monitoring, Railway environmental monitoring, automobile making, marine environmental monitoring, transport environment monitoring, environmental scientific researches, inspection room, used in laboratory.

Instrument application range:
The equipment is mainly used in the measurement of oil content in the surface water, groundwater, industry waste water, which also can be used in the oil monitoring of smoke in catering industry and monitoring of oil content in the solid. This instrument is professional instrument to measure the oil content in water, gas, solid.

Technical index
Item Description
Detection limit 0.02mg/L(calculate 3 times standard deviation measuring 11 times blank)
wave-number range 3400cm-1~2400cm-1(2941nm~4167nm)
Absorbency range 0.0000~2.0000AU (transmittance 100~1%T)
Minimum detectable concentration 0.001mg/L (enrichment extraction method)
Maximum measured concentration 10000mg/L (dilution gaging)
Instrument measurement range (0.05~120)mg/L
Repeatability RSD1% (20-100mg/L Oil sample determined 11 times)
Measurement accuracy error <±2 %
Related coefficient R>0.999
The wave number accuracy and wave number repeatability ±1cm-1
Main machine net weight 13kg
Power supply (220±22)V, (50±1)Hz,50VA
temperature and humidity Temperature range: 1ºC-40ºC, humidity80%
Main machine external dimension 450mm×350mm×130mm

Main instrument characteristics:
1. Using Windows XP, vstart or Windows 7 operating system control.
2. Have the function of measuring instrument correction coefficient.
3.Adopt advanced USB2.0 interface technology.
4. It is suitable for oil detection in the water on field spots after installed UPS, which also could be installed extract unit to upgrade to fully automatic infrared spectral oil analyzer.
5. True three wave number, clear infrared three wave spectrum diagram, accuracy scale, could clearly display absorb spectrum diagram and absorbance produced by three wave numbers.
6. To inspect light transmittance and purity of extraction agent, can distinguish various distractions
7. Electric speed controller , replacing light source machinery switch, improve instrument reliability.
8. Adopt high performance pyroelectric infrared detectors, accurately gather the signal of pyroelectric current formed in the circuit when halogen lights are lighting and out.
9.Good related coefficient, measurement 0.5-5 mg\L,R>0.999.
10. Have the function of automatic statistical analysis, spectrogram display, storage, printing, etc
Instrument application field and application of national standard
Application units National standard
The determination of environmental monitoring station, sewage and industrial wastewater GB8978 - 1996 integrated wastewater discharge standard
catering lampblack monitoring unit GB18483 - 2001 catering lampblack
emission standard
Municipal drainage station or sewage
treatment plant
GB18918 - 2002 municipal sewage treatment plant contaminant emission standard
Urban water supply company or running-water company GB3838 - 2002 surface water quality standard
Petrochemical industries GB3551 - 83 petroleum refining industrial water contaminant emission standard
Railway environment monitoring station GB5469 - 85 wagon Washing wastewater emission standard
thermal power plant environmental monitor station GB8978 - 1996 integrated wastewater emission standard and other standard
smelting industry waste water monitoring GB13456 - 92 steel industrial water  contaminant emission standard
marine fishery water quality monitoring GB3097 Sea water quality standard and GB11607 water quality standard of fishery
hydrological environment monitoring station GB3838 - 2002 surface water environmental quality standards
Agricultural products quality supervision and inspection center and Agricultural forestry environment monitoring station GB4284 - 84 agricultural sludge pollution control standards

Woa-900 Infrared Spectroscopy Petroleum AnalyzerWoa-900 Infrared Spectroscopy Petroleum AnalyzerWoa-900 Infrared Spectroscopy Petroleum AnalyzerWoa-900 Infrared Spectroscopy Petroleum Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now