Automatic Breaking Point Tester (Fraass Method)

After-sales Service: One Year Free Parts
Warranty: One Year
Power Supply: AC(220±10%)V, 50Hz
Refrigeration Mode: Low Temperature Circulatory Bath
Cooling Rate: (1±0.5)ºC/Min
Temperature Measuring Range: -30ºC~25ºC
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PT-ASP-0613A
Temperature Measuring Error
±0.5ºC
Steel Slice
41mm×20mm×0.15mm
Test Samples
It Can Determine 3 Samples at The Same Time
Transport Package
Plywood Packing
Specification
Overall dimension: 500mm× 400mm× 570mm
Trademark
Xiangyi
Origin
China
Production Capacity
100 PCS/Month

Product Description

Summary
This instrument is used to determine the temperature which bitumen tends to break rather to flow when cooled and stressed as per standards GB/T 4510 and JTG E20-2011. It can do three tests at the same time in the same environment and calculate the average value. The cooling rate is controlled by computer.

I. Main technical features
It is controlled by micro computer. The cooling rate is controlled automatically. It automatically timing to bend samples. The test data is shown on the colored LCD and outputted by built-in printer.

II. Main technical specifications
1. Power supply:      AC(220±10%)V,50Hz
2. Refrigeration mode:     Low temperature circulatory bath
3. Cooling rate:     (1±0.5)ºC/min
4. Temperature measuring range:     -30ºC~25ºC
5. Temperature measuring error:     ±0.5ºC
6. Steel slice:  41mm×20mm×0.15mm
7. Test samples:   It can determine 3 samples at the same time.
8. Ambient temperature:    Room temp. ~+30ºC
9. Relative humidity:     ≤85%
10.Power consumption:    450W(breaking point tester)+ 1600W(low temperature circulatory bath)
11.Overall dimension:     500mm×400mm×570mm(breaking point tester)

Note: We can customize the breaking point tester with measuring range:-40ºC~25ºC

III. Standard Accessories
No. Item Unit Qty
1 HWY-15 type  HypothermiaCirculating thermostatic bath Set 1
2 Stainless steel specimen Piece 6
3 Rubber pipe(Ф10×1 m) Piece 2
4 Temperature protection pipe(Ф15×1 m) Piece 2