• -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
  • -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
  • -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
  • -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
  • -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
  • -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump

-105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump

After-sales Service: Free Spare Parts
Warranty: One Year
Type: Water-Cooled
Cooling Method: Water-cooled
Unit Structure: Integral
Selected Voltage: 220V50Hz/380V 50Hz
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LRC Series
Compressor Number
1
Noise Level
Low
Application Fields
Electronic
Application Machine
Laser Equipment,Plasma Welding
Certification
RoHS, ISO, CE
Condition
New
Medium Temperature Range
-105°c ~ -60°c / -120°c ~ -70°c
Communication Protocol
Modbus RTU Protocol, RS 485 Interface
Model
Lrc Series
Transport Package
Export Packing
Trademark
Xiangyi
Origin
China
HS Code
8418692090
Production Capacity
100 PCS/Month

Product Description

 -105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller PumpTypical Applications:
 Semiconductor Manufacturing Device Cooling:
Single chip cleaning, printing machine, automatic clamp installation equipment, spraying equipment, ion plating equipment, etching device, single-chip processing device, slicing machine, packaging machine, the temperature of the developer management, exposure device, magnetic part of the heating device, etc.
 Laser Equipment Cooling:
Laser processing, heating part of the welding machine, laser marking device, chemical reaction plant, carbon dioxide laser processing machine, etc.
 Other Industries Cooling:
Plasma welding, automatic packaging machine, mold cooling, washing machine, gold-plated groove, resin molding machine, precision grinding machine, injection molding machine of molding parts, etc.
 Analysis Of Testing Machine Cooling:
Electronic microscope, ICP lighting light source part of the spectrum analysis device, heating part of the spectrophotometer, X-ray analytical device of heat source, automatic pulse heating part of the banner, the light source of atomic absorption spectrophotometer, etc.
CNC machine, machining center cooling of the cooling medium.
-105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump

Features
  • Saving resources; closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.
  • Multi-safety protection, more reliable operation.
  • Brand compressor, cascade refrigeration cooling technologies.
  • Human design, more convenient and flexible.
  • Efficient two-condensate system.
  • Computer-cascade temperature controller, temperature figures display, adjustable unit is 0.1°C, temperature range is -25°C to room temperature,PT100 temperature sensor.
  • Use of cold technology, can guarantee the stability of temperature at low temperature.
  • Can set the temperature difference of compressor on/off.
  • Monitoring the ambient temperature, prevent temperature to be higher in the running system.
  • 10.A variety of fault alarm (over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm).
  • Power on delay protection, three-level cascade system protectors.
  • All parts are safety grounding.
  • Adopt full closed circulation design, no water vapor at low temperature and ensure the purity of cooling medium, in case of ice crystals, provide a long time life of heat transfer liquid.
  • High-performance circulating pump, can guarantee 24 hours continuously running a day.
  • Use plate cool-heat-exchanger, heat transfer efficiency is provided.
-105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump
-105° C ~ -60° C / -120° C ~ -70° C Low Temperature Circulation Enclosed Chiller Pump

Technical Parameters:
-105°C ~ -60°C / -120°C ~ -70°C
Model LRC-A025WN LRC-A050WN LRC-A080WN LRC-A215WN LRC-A230WN LRC-A255WN
Medium Temperature Range -105°C~-60°C -105°C~-60°C -105°C~-60°C -120°C~-70°C -120°C~-70°C -120°C~-70°C
Temp. control ASET multifunctional controller
Temp. control optional Heat-conducting medium outlet temp. control
communication protocol MODBUS RTU Protocol, RS 485 Interface
Temp. feedback Heat-conducting medium temperature feedback PT100
Cooling capacity -60°C 2.5kW 5kW 8.6kW      
-75°C 1.3kW 3kW 5kW 1.2kW 2.4kW 4kW
-95°C 0.7kW 1.4kW 2.3kW 0.7kW 1.4kW 2.1kW
-110°C       0.3kW 0.55kW 0.95kW
Circulation pump Max20L/min
0.7BAR
Max35L/min
1BAR
Max75L/min
1BAR
Max20L/min
0.7BAR
Max35L/min
1BAR
Max35L/min
1BAR
capacity of liquid storage 15L 20L 35L 20L 30L 30L
Compressor Tecumseh Copeland Copeland Copeland Copeland Copeland
Evaporator Plate heat exchanger
Operating controller 7-inch color touch screen display, temperature curve record, excel format export
Security protection Self-diagnosis function; freezer overload protection; high pressure switch;
overload relay, thermal protection device etc. security protection function.
Refrigerant R-404A
Connection size DN-15 DN20 DN20 DN20 DN20 DN-20
Product size (water-cooled) 500*680*1350 600*700*1650 700*700*1650 600*700*1650 700*700*1650 1000*900*1650
Weight (water-cooled) 235kg 320kg 455kg 340kg 380kg 480kg
Power AC380V 50HZ
5.5kW (max)
AC380V 50HZ
7.5kW (max)
AC380V50HZ
11kW (max)
AC380V 50HZ
6kW (max)
AC380V 50HZ
9.5kW (max)
AC380V50HZ
14kW (max)
Material Cold rolled steel painting
Optional Circulation Pump Optional: 35L/min 2.5bar 50L/min 2.5bar 110L/min 2.5bar
Optional SUS304 material
Optional Pressure <=6 bar circulating pump
Optional Power 220V 60HZ three-phases, 440V~480V 60HZ three-phases
Remark Can make the bigger capacity of water storage as required.


Technological Process 
-105&deg; C ~ -60&deg; C / -120&deg; C ~ -70&deg; C Low Temperature Circulation Enclosed Chiller Pump
-105&deg; C ~ -60&deg; C / -120&deg; C ~ -70&deg; C Low Temperature Circulation Enclosed Chiller Pump



Packing
-105&deg; C ~ -60&deg; C / -120&deg; C ~ -70&deg; C Low Temperature Circulation Enclosed Chiller Pump

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now