Basic Info.

Model NO.
SI-2000TD1-K
Test Principle
Expansion of The Gas Displacement Method;
Test Content
True Density; Foam, Rigid Foam Opening Rate
Test Accuracy
Accuracy Better Than ± 0.04%
Repeatability
Better Than ± 0.02%
Resolution
0.0001g / Ml
Transport Package
Plywood Case
Specification
H610 * W450 * L550mm; 25kg
Trademark
Xiangyi
Origin
China
HS Code
9027809900
Production Capacity
100

Product Description

Automatic Open and Closed Porosity True Density Analyzer
 

SI-2000TD-K automatic open and closed porosity true density analyzer uses computer-controlled automatic operation of the gas expander true density analysis system, with a number of technology patents, the original test mode, so that a wider application area than similar instrument , can accurately determine true density, density and porosity of the powder, bulk solids, syrupy substance, foam and other materials,
 
Features and Benefits
  1. open closed porosity dedicated sample cell: a sample cell foam material specifically meet the national standard GB / T 10799-2008 and design, stainless steel, the interior space of a cube, can sample cell utilization rate (more than 80% of the national standard more than 15%), much higher than ordinary cylindrical sample cell;
  2. Test method: different volumes of sample cell as a sample test chamber "downloading" type of test mode, relative to similar instruments by filling way to change the way the test chamber volume, with the sample test chamber volume high utilization advantage, so that the test accuracy can be improved; "Bottoms bayonet," the sample cell, can meet the micro-volume and large volume sample loading demand convenience, in order to achieve the purpose of improving the accuracy of the test;
  3. (Patent Title: having a sample cell directly as real test chamber densimeter Patent No.: 201120436207.5)
  4. Valve Type: gas control valves, fundamentally eliminate the solenoid valve structure similar instrument operation when the heat caused by the temperature change of the reference cavity and temperature non-uniformity, ensuring the ideal temperature effect; the use of software to subvert the fundamental Fixed way to reduce electromagnetic valve damage thermostat heating effect caused by error;
  5. (Patent Name: precision pneumatic valve having a true density gauge patent number: 201220140709.8)
  6. modular manifold: no air passage between the modular structure, valves and valve pipe joints, reducing the leakage point, temperature field uniformity;
  7. Auto Repeat: You can automatically repeat the test until the specified accuracy;
  8. pressure balance: with automatic default, and the user selects a user-defined three modes of pressure equilibration time to adapt to the structural state of the sample do not;
  9. self-test process: advanced intelligent self-test process, intelligent judgment sample cell for leaks and instrument tightness is qualified to solve human error;
  10. restore normal pressure: a pressure test is completed automatically restore function to prevent splashing the sample;
  11. Control Interface: a clear image of graphical control interface, and can perform all operations on the hardware control interface;
  12. power protection: super stability, even if unexpected power outages, break, and will not lose the current data, and experiments recoverable proceed;
  13. Memory function: the instrument configuration parameters is written directly to the instrument hardware chip, stored permanently, and reinstall the system, do not worry instrument parameters are missing or incorrectly configured, to achieve zero artificial instrument hardware configuration parameters;
  14. Run Log: detailed running log instrument time accurate to the second, the log for the reliable operation of the instrument to provide protection and after-sale;
  15. live voice: each test process real voice prompts;l
  16. Multi-language package: support customizable editable multi-language interface;
  17. Remote Control: a network remote control function; 
Performance parameters
  • Test principle: expansion of the gas displacement method;
  • Test content: true density; foam, rigid foam opening rate, closed porosity, holes opening ratio correction, aperture correction obturator rate cut; meet the national standard GB / T 10799-2008;
  • Test accuracy: accuracy better than ± 0.04%, repeatability better than ± 0.02%, Resolution: 0.0001g / ml;
  • Test volume range: 0.01 ~ 2000ml
  • Test speed: Single Station 0.5-1min completing a test (without holding time). Double station double the efficiency analysis;
  • Analysis stations: one analysis station, and a test sample;
  • Scope: density of the sample size is not limited, the true density can be measured a variety of powder, granular, massive, like a foamy solid samples, as well as syrupy substance, and other non-volatile liquid sample; foam materials open closed porosity of the material;
  • Test Volume: 0.01ml or more, for a variety of sample volumes; be equipped with micro-volume sample cell (with corresponding micro-cavity volume basis) for small samples; use directly as the test sample cell cavity patented technology, the sample volume is not test chamber volume restrictions;
  • Double reference chamber: having built a reference chamber, an expansion chamber (expansion chamber for different sample cell volume to change the reference chamber volume to improve the measurement accuracy); program whether to enable the expansion chamber according to the remaining volume is automatically selected ; double reference cavity volume is to ensure a wide range of test accuracy;
  • Pressure equilibration time: with automatic default, and the user selects a user-defined three modes of pressure equilibration time to adapt to the structural state of the sample do not;
  • Pressure range: 0-1bar. Users can customize the maximum pressure, the pressure to reduce the error caused by deformation analysis of samples;
  • Fully automated: a key to complete the circuit-switched and gas flushing, flushing the sample pretreatment system thermostat, repeated testing, gives the result;
  • Thermostat mode: Automatic mode programmable thermostats, temperature accuracy error <0.1 ºC; programmable thermostat to control the process, and automatically enters the testing process;
  • Sample cell: standard 10ml, 50ml, 150ml of the true density of the sample cell. Another also easily be extended to 2000ml (with automatic switching correspondingly large volume expansion chamber); Special requirements can be customized a variety of sample cell;
  • Sample cell installation: Bottoms formula (patent pending number: 201120436207.5); to test the sample cell as a sample chamber, the sample test chamber has the advantages of high volumetric efficiency, so that the test accuracy can be improved; "Bottoms bayonet "type of sample cell to meet the needs of large volume sample loading, so as to improve test accuracy.
  •  Auto Repeat: You can automatically repeat the test until the specified accuracy;
  • Self-test process: advanced intelligent self-test process, intelligent judgment sample cell for leaks and instrument tightness is qualified to solve human error;
  • Test gas: 40 elevated pure helium, purity ≥99.999%; other gases such as nitrogen optional; not easy to use cylinders of environment, optional gas generator;
  • Equipment accessories: patented modular gas control valve manifold; valves and pressure sensors of all imports;
  • Appearance of the instrument: H610 * W450 * L550mm; 25kg
model SI-2000TD1-K
Appearance of the instrument H610 * W450 * L550mm; 25kg
Resolution 0.0001g / Ml

Automatic Open and Closed Porosity True Density Analyzer
Automatic Open and Closed Porosity True Density AnalyzerAutomatic Open and Closed Porosity True Density AnalyzerAutomatic Open and Closed Porosity True Density AnalyzerAutomatic Open and Closed Porosity True Density Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More