Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle

Product Details
Customization: Available
After-sales Service: Free Spare Parts
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
36
Year of Establishment
2005-04-06
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
  • Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
Find Similar Products

Basic Info.

Model NO.
SIT2000B2
Tension Measuring Range
Surface and Interfacial Tension 1X10-5 -100mn / M
The Reading Range
0-4mm
Reading Accuracy
0.001mm
Speed Control Range
1000-10000r / Min Accuracy: 0.1%
Transport Package
Plywood Case
Trademark
Xiangyi
Origin
China
HS Code
9027809900
Production Capacity
100

Product Description

Spinning drop interfacial tension contact angle measurement is based on the latest research results of domestic surface and colloid chemistry experts, integrated the advantages of similar products at home and abroad, using computer control and multimedia technology in the new millennium of the latest research and development of products. The instrument uses a spinning drop method; It is a special equipment to measure the surface tension of liquid, liquid / liquid interfacial tension and liquid / solid contact angle. The main application areas are: EOR (chemical flooding) indoor study and site monitoring; study of surfactants, detergents, emulsions and foams; research fuel oil, lubricants, paints, inks and coatings; paper products, photographic research materials, pesticides, etc.,
Main application areas
1. EOR (chemical flooding oil) indoor and field monitoring study
2. surfactants, detergents, emulsions and foams study
3. Study of fuel oil, lubricants, paints, inks and coatings
4. Research paper products, photographic materials, pesticides etc
 
Feature
1. The whole process is controlled by PC computer and a pre-SBC, the use of computer multimedia video technology to collect spinning drop of image analysis,
2. The master program is a Windows interface, easy operation, the image as a standard BMP file that can be stored in print.
3. The tension measurement wide range, from 10-5mN / m to 100mN / m, across seven orders of magnitude, the meter full scale tension.
4. The high accuracy, providing the number of stalls magnification, hair width can be enlarged to over one hundred pixels, greatly improve the measurement accuracy of ultra-low interfacial tension.
5. One machine can measure the interfacial tension and contact angle, thereby performing wet ability studies. For contact measurement under normal circumstances, the instrument can make liquid droplets in a regular rotation of the body, thus ensuring measurement precision and accuracy. In addition, it can also be measured when the contact angle of the liquid / liquid interfacial tension of ultra-low value, and very convenient, this is the other contact angle measuring instrument difficult to do.
6. With electric heating temperature control system, capable of constant temperature experiments.
 
Technical Specifications and Features
1. Tension measuring range: surface and interfacial tension 1x10-5 -100mN / m
2. The reading range: 0-4mm (2mm and 4mm provides high-purity quartz sample tube)
3. Reading Accuracy 0.001mm
4. Speed control range 1000-10000r / min Accuracy: 0.1%
5. Temperature display range: 0-100 ºC (built-in heating RT + 5 ºC to 80 ºC or external bath temperature)
6. Temperature display accuracy: ± 0.1 ºC
7. Computer and stand-alone real-time set temperature and speed
8. The video detection system Resolution: 768x576
9. The video capture rate: 25 frames / sec.
10.RS-232 serial port (test data); VIDEO RCA Interface (video capture)
11.220V / 50 Hz or 110V / 60Hz

SIT2000B2 spinning drop interfacial tension / Intravenous contact angle measuring instrument (dual-use) can be used to measure the contact angle of a liquid on a solid, that is a liquid wet ability on solid, can also use the spinning drop method to measure the surface tension of the liquid, liquid / liquid interfacial tension. The instrument consists of two separate parts, a common optical video system.
Spinning Drop Interfacial Tension Meter/ Intravenous Contact Angle

Spinning Drop Interfacial Tension Meter/ Intravenous Contact AngleSpinning Drop Interfacial Tension Meter/ Intravenous Contact AngleSpinning Drop Interfacial Tension Meter/ Intravenous Contact AngleSpinning Drop Interfacial Tension Meter/ Intravenous Contact Angle
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More